Liquid Cooling Systems

Direct Liquid Cooling

Motivair Cooling Solutions

Liquid Cooling Systems for High-Performance Computing

Market demands & technological advances are driving a growing need to use liquid-cooled servers. Artificial Intelligence. Big Data. Internet of Things. Remote work. Hyper-converged Infrastructure. These technologies are accelerating, and with them the need for increasing CPU & GPU power densities.

Motivair’s Liquid Cooling Technology allows you to leverage increased processing power while using less energy and space than traditional air-cooled systems.

Increased Processing Power

Gain More Efficieny

Lower Operating Costs

Data Center & Liquid Cooling Portfolio

Motivair’s End-to-End Cooling Solutions for High-Performance Computing, Data Centers & IT Infrastructure are an all-in-one liquid cooling solution, providing products and the post-sales service for the entire lifetime of your cooling infrastructure. We leverage over 30 years of experience in mission critical cooling to deliver:

  • Expert Installation and Start-Up Services for Mission Critical Facilities or Processes
  • Cutting-Edge Technology Providing Maximum Uptime
  • Reliable Post-Sales Support and Maintenance

Liquid Cooling for Compact or TDS Systems

For 1x rack high-density servers or TDS rack (test and development system), small systems, requires building cooling system.



Dynamic Cold Plates™


In-Rack Manifold
Quick Connects & Hoses


In-Rack CDU


End-to-End Solution

Liquid Cooling for Medium-to-Large Systems

For larger HPC clusters or larger deployments of high-density servers. Requires building cooling system.



Dynamic Cold Plates™


In-Rack Manifold
Quick Connects & Hoses


Coolant Distribution Unit


End-to-End Solution

Convert Liquid to Air Cooling

For small, medium, or large high-density servers or simply liquid-cooled servers, used when building cooling water is not available. Ideal for large enterprise or co-lo data centers designed for 100% direct air cooling.



Dynamic Cold Plates™


In-Rack Manifold
Quick Connects & Hoses


Heat Dissipation Unit™


End-to-End Solution

Frequently Asked Questions

What are the advantages of liquid cooling over air cooling?
Liquid cooling allows you to take advantage of deploying more servers per rack, lower power usage and increased processing power.

What is an End-to-End Cooling System?
Motivair’s End-to-End Cooling Solutions for High-Performance Computing, Data Centers & IT Infrastructure are an all-in-one, closed loop, direct liquid cooling solution, providing products and the post-sales service for the entire lifetime of your cooling infrastructure.

What is a closed loop?
A closed loop system isolates and removes heat from inside an enclosure, preventing mixing with ambient air.

What is the difference between a CDU and an HDU?
A Coolant Distribution Unt (CDU) rejects heat from the server rack to the chilled water loop of the building. A Heat Dissipation Unit™ (HDU) rejects the server heat from the server rack to the white space where building air conditioning would then remove that heat.

Does Motivair provide partners and customers with support services and warranty?
Depending on your warranty coverage needs, comprehensive parts coverage can be extended out from 2 to 5 years from the date of original purchase depending on product type and model. Extended Parts Warranty coverage can be pre-purchased any time prior to authorized factory start-up through your authorized Motivair partner.

Extended Parts Warranties require a Preventative Maintenance program to be maintained throughout the warranty period. Choosing to extend your parts warranty coverage offers a simple and cost-effective way to avoid unexpected expenses should an event occur requiring parts to be replaced.

Connect with your local Motivair product specialist today.